Sensor Specifications HI7698194-0 HI7698194-1 HI7698194-3 HI7698194-2 Description pH sensor pH/ORP sensor EC sensor DO sensor Measurement Type pH, mV (pH) pH, mV (pH), ORP EC DO (% saturation and concentration) Measurement Range 0.00 to 1Ð.00 pH; ±600.0 mV 0.00 to 12.00 pH; ±600.0 mV; ±2000.0 mV 0.0 to 200.0 mS/cm; 0.0 to 400 mS/cm (absolute) 0.0 to 500.0 %; 0.00 to 50.00 mg/L Temperature Range -5 to 55°C -5 to 55°C -5 to 55°C -5 to 55°C Color Code red red blue white Materials Tip glass (pH) glass (pH); Pt (ORP) stainless steel electrodes AISI 316 cat/an: Ag/Zn Glass Type LT (low temperature) LT (low temperature) — — Junction ceramic ceramic — membrane: HDPE Body PEI PEI ABS/epoxy white top ABS Electrolyte gel gel — — Reference double double — — Maintenance Solution HI70300 (storage solution) HI70300 (storage solution) none HI7042S (DO electrolyte) Dimensions 118 x 15 mm 118 x 15 mm 111 x 17 mm 99 x 17 mm Depth 20 m (65’) 20 m (65’) 20 m (65’) 20 m (65’) or Probe Specifications HI7698194 Sensor Inputs three (pH or pH/ORP, DO, EC) Sample Environment fresh, brackish, seawater Waterproof Protection IP68 Operating Temperature -5 to 55°C Storage Temperature -20 to 70°C Maximum Depth 20 m (66’) Dimensions (without cable) 342 mm (13.5”); 46 mm (1.8”) dia Weight (without sensors) 570 g (20.1 oz.) Cable Specification multistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb.) intermittent use Wetted Materials Body ABS Threads Nylon Shield ABS / 316 SS Temperature Probe 316 SS O-rings EPDM Multi-function Sensor • Quick sensor replacement · Sensor replacement is quick and easy with field replaceable, screw type connectors and are color coded for easy identification. These meters automatically recognize sensors. Probe and Sensors The HI7698194 is a multiparameter pH/EC/DO/Temperature probe for use with the HI98194 portable meter. It features a Quick Connect DIN that makes a waterproof connection with the meter. Sensors are automatically recognized by the probe and meter when connected. Any ports not used on the probe will not have the parameter displayed on the meter. Sensor replacement is quick and easy with ¯eld replaceable, screw type connectors that are color coded for easy sensor identi¯cation. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. It’s rugged, waterproof design makes it ideal for ¯eld use. HI9828-25 Quick Calibration solution • Optional shockproof silicon rubber boot · Specially designed to protect your instrument from damage or impact HI710034 Orange 7 Multiparameter 7.64 | www.hannainst.com portable
RkJQdWJsaXNoZXIy MTI3NTM=